Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Schiller |
Model Name/Number | Cardiovit AT-102 G2 |
Machine Type | Resting |
Operating Mode | Automatic |
Number Of Channels | 12 Channels |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Weight | 378 x 326 x 108 mm 4 kg approx |
Rechargable Battery | Yes |
Ecg Lead Annotation | Yes |
Accessories | Power Cord |
Built In Printer | Yes |
Number Of Channels | 12 Channels |
Brand | schiller |
Machine Type | Digital |
Digital Display | Yes |
Model Name/Number | Schiller Cardiovit At 102 Plus Ecg Machine |
Digital Filtering | Yes |
System Parameter | Value |
---|---|
Dimensions (l/w/h) | 378 x 326 x 108 mm |
Weight | Approx. 4.4 kg including rechargeable battery and paper |
Power | Mains or battery operation |
Voltage | 100 to 240 V |
Current | Max. 1.0 A (115 V) to 0.16 A (240 V) |
Frequency | 50/60 Hz |
Battery type | Rechargeable Lithium-polymer battery, replaceable by the user, battery capacity for 100 ECG printouts or 3 hours of continuous display (without printing) |
Battery recharging time | Approx. 3 hours after full discharge (with device switched off) |
Power consumption | Approx. 60 VA |
Line frequency filter | Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by adaptive digital filtering |
ECG amplifier | Sampling frequency: 4000 samples/second/channel Measuring range: Dynamic +/- 10 mV, DC +/- 300 mV Pacemaker detection: > +/- 2 mV / duration > 0.1 ms Frequency range: 0.05 Hz - 150 Hz (IEC/AHA) CMRR: > 100 dB Digital resolution: 5 μV / 18 bit Input impedance: 100 MOhm Patient leakage current: < 5 μA Patient input circuit: Fully floating and isolated, defibrillation protected Defibrillation protection: 5000 VDC |
Special recording functions | Detection of loose electrodes, electrode impedance, overvoltage, AC noise, baseline fluctuations and muscle tremor Heart rate measurement: up to 300 beats per minute |
Standard interfaces | RS-232 (V24) serial interface: Spirometry (Spirovit sensor 250 or 260) |
Communication | SCM (SCHILLER Communication Module): Communication with SEMA-200 via: Ethernet (LAN) RJ-45 connector optional GPRS optional WLAN module with integrated antenna, supports 802.11g, WPA, WPA2, WEP and SSID (invisible) |
Internal memory | 350 ECG recordings |
Long-term rhythm recording | 5 minutes memory: The signals of the past 5 minutes for all ECG channels (full disclosure) can be saved in the memory and transmitted to SEMA. |
Filters | Myogram filter: Adjustable to 25 or 35 Hz SSF: SCHILLER Smoothing Filter SBS: SCHILLER Baseline Stabiliser |
Display | Splash-proof and dust-protected colour LCD screen with LED backlight, diagonal 8,4 inch (215 mm) Display resolution: 800 x 600 pixels Display data: Heart rate, patient name, patient number, time, curves, lead designations, speed, amplification, filter settings and warnings Number of leads displayed on the screen: 3, 6, 2x6, 3x4+1 rhy and 12 Lead combinations: Up to 12 simultaneous leads: Standard/Cabrera/Nehb; more lead combinations freely programmable by the user |
Printer | Printing technology: High-resolution thermal printing, 8 dots/mm (amplitude axis), 40 dots/mm (time axis), @ 25 mm/s Frequency range: 0.05Hz - 150Hz (IEC/AHA) Chart speed: 5, 10, 25 and 50 mm/s Sensitivity: 5 |
Additional Information: